NOTE: Not all VF-3 to VF-5 with the work table option will experience the light flickering. Upgrade to the 200W power supply, order 93-3521 and follow the 24V Work Light - LVPS - Replacementprocedure. The machine has a 100W power supply for the work lights installed.ĭO NOT REPLACE THE TABLE WORK LIGHT. On Medium VMC's (VF-3 to VF-5) the 24V Work Table Light flickers when machine comes on, or when commanded to turn on. Also make sure there is a ferrite filter installed on the regen cable. Make sure the Hil/Worklight cable is routed on the left side of the cabinet. This applies only to the 24VDC HIL/Worklight assemblies. Problem with the HIL/Worklight cable routing or missing ferrite filter. Go to Diagnostics / Keyboard I/O page and toggle the button, if the bit does not toggle in diagnostics check the switch operation with a ohm meter. Problem with the worklight or HIL momentary button. If flickering continues, replace the LED assembly. If the LED is flickering on and off, re-seat the connections. If the voltage is correct, and the LED does not work, it must be replaced. Check for 120 VAC or 24 VDC at the fixture connector. For machines with 24VDC LED lamps: 74-0078Ĭheck the light for damage.For machines with 120VAC LED lamps: 74-1807.If the receptable need to be replaced order the following part number: If the machine has a GFCI, check if the GFCI is tripped. Problem with the GFCI circuit/receptacle.